FED (Far East District) 美 극동공병단 - 한국에 주둔하고 있는 주한미군들을 위한 사업에 투입되는 시설에 사용되는 배전용 케이블입니다. UL이 요구하는 사양 및 품질에 적합한 제품을 생산 공급 합니다.
600V Heat-Resistant PVC Insulated Wire
Application
Type THW listed by UL is suitable for use in wet and dry locations at 75℃
This wire is generally used in conduit or other approved raceways in commercial wiring, as specified in the National Electrical Code.
Standard
UL83 Thermoplastic insulated wires and cables
Construction
Conductor Solid or stranded annealed copper
Insulation Flame-retardant, Heat-, Abrasion- and moisture-resistant PVC
Color
The standard color is black, when required for a particular application, other colors are available
600V Heat-Resistant PVC Insulated and Nylon Jacketed Wire600V Heat-Resistant PVC Insulated Wire
Application
Type THHN is suitable for use in dry locations at 90℃
Type THWN is suitable for use in dry and wet locations at 75℃
These wires are generally used in conduit as branch circuits in commercial or industrial applications, as specified in the National Electrical Code.
Standard
UL83 Thermoplastic insulated wires and cables
Construction
Conductor Solid or stranded annealed copper
Insulation Flame-retardant, Heat-, Abrasion-and moisture-resistant PVC with clear nylon jacket
Color
The standard color is black, when required for a particular application, other colors are available
600V Flame-Retardant XLPE Insulated Wire
Application
Type USE-2 listed by UL is suitable for use in wet and dry locations at 90℃
This wire is generally used for distribution and branch circuit wiring in commercial and residential applications with conduit as specified in the National Electrical Code.
Standard
UL854 Service-Entrance Cables
UL44 Thermoset insulated wires and cables
Construction
Conductor Solid or stranded annealed copper
Separator A separator may be applied on stranded conductor
Insulation Flame-retardant, heat-, abrasion-and moisture-resistant crosslinked polyethylene(FR-XLPE)
Color
The standard color is black, when required for a particular application, other colors are available
Weather Proof PE Insulated Wire
Application
WP is intended primarily for the distribution of electrical energy under normal conditions of overhead installations and service outdoors.
The coverings carry no voltage ratings, and the conductors must be installed on insulators adequate for the service voltage.
Standard
ICEA S-70-547 Weather-resistant Polyethylene covered conductors
Construction
Conductor Hard-drawn Solid or stranded copper
Insulation Polyethylene
Color
Black
5kV, 8kV Copper Conductor XLPE Insulated, and PVC or PE jacketed power cable
Application
Type MV-90℃ Cable is used for 5kV,8kV power and distribution circuits in industrial and commercial installation.
It may be installed on conduit, duct, tray or directly buried. Safe from ingress of humidity.
Standard
UL1072
Construction
Conductor Circular compacted stranded plain annealed copper
Insulation 90℃, extruded cross-linked polyethylene with semi conductive inner and outer screen
Metallic Screen Annealed copper tape
Sheath Black PVC or PE
15kV Copper Conductor XLPE Insulated, and PVC or PE jacketed power cable
Application
Type MV-90 Cable is used for 15kV power and distribution circuits in industrial and commercial installation.
It may be installed on conduit, duct, tray or directly buried. Safe from ingress of humidity.
Standard
UL1072
Construction
Conductor Circular compacted stranded plain annealed copper.
Insulation 90℃ ,extruded cross-linked polyethylene with semi conductive inner and outer screen.
Metallic Screen Annealed copper tape
Sheath Black PVC or PE.
25kV Copper Conductor XLPE Insulated, and PVC or PE jacketed power cable
Application
Type MV-90 Cable is used for 25kV power and distribution circuits in industrial and commercial installation.
It may be installed on conduit, duct, tray or directly buried. Safe from ingress of humidity.
Standard
UL1072
Construction
Conductor Circular compacted stranded plain annealed copper
Insulation 90℃ ,extruded cross-linked polyethylene with semi conductive inner and outer screen
Metaillc Sreen Annealed copper tape
Sheath Black PVC or PE
Soft Drawn Bare Copper Conductor / Hard Darwn Bare Copper Conductor
Application
Type SDBC/HDBC listed by UL is suitable for use in electrical properties
Standard
ASTM B8 Standard specification for Stranded Copper Conductors
Construction
Conductor Stranded annealed copper wires
저온에서 고온까지의 온도 범위에서 열전대와 거의 유사한 열기전력 특성을 갖는 한 쌍의 도체에 절연을 하여, 열전대의 단자와 기준 접점 사이를 접속하여 열전대의 단자 부분의 온도 변화에 따라 생기는 오차를 보상하기 위한 전선이며, 발전소, 석유화학공장, 제철 제련소, 소형 보일러 등 열관리를 필요로 하는 모든 산업분야에 사용됩니다.
● 케이블 정격 : 0.6/1kV 90℃
● 적용규격 : UL Subject 44, IEC 60228
● 도체등급 : 주석도금 연동연선(CLASS 2, CLASS 5)
● 난연성 : (UL) VW-1, VTFT
Type | Material | Limit of error (Temp. Range) | ||
KSC 1609 (JISC 1610) | ANSI MC 96.1 | |||
K Chromel/Alumel | KX | (+)Chromel (-)Alumel | ±2.5℃ (-20~150℃) | ±2.2℃ (0~200℃) |
K Chromel/Alumel | EX | (+)Chromel (-)Constantan | ±2.5℃ (-20~150℃) | ±1.7℃ (0~200℃) |
K Chromel/Alumel | TX | (+)copper (-)Constantan | ±2.5℃ (-20~150℃) | ±1.0℃ (-06~200℃) |
K Chromel/Alumel | JX | (+)iron (-)Constantan | ±2.5℃ (-20~150℃) | ±2.2℃ (0~200℃) |
R Platinum-Rhodium Platinum | RX | (+)Copper (-)Cu-Nickel alloy | ±3˚c~7℃ (0~100℃) | ±25℃ (0~200℃) |